RWC

Air Cooled Residential Chiller with Scroll Compressor

Air Cooled Residential Chiller with Scroll Compressor

PETRA RWC Chillers are designed to meet customer requirements by offering state of the art low sound, reliability, high energy efficiency and small physical footprint chillers. The wide range of cooling capacities and flexible installation arrangement makes it easy to install and maintain.

PETRA RWC Chillers are designed to be shipped as a complete factory package which are 100% run tested in the factory.

PETRA RWC4 Chillers are equipped with an intelligent microprocessor controller to manage the unit performance for optimum efficiency at both full load and part load values.

  • Welded structural base painted with mono component catalyzed primer sprayed paint.
  • Base is equipped with welded brackets for heavy duty lifting lugs.
  • High performance hermetic scroll compressor.
  • Condenser coils are copper tubes copper aluminum type.
  • All coils are air pressure tested by dry air up to 2,900 kPa (420 Psi) under water. They also undergo dry cleaning after manufacturing for optimum system cleanness.
  • Condenser fans of the external rotor type with many attractive features such as space saving, compact design, optimum cooling, full speed controllability and low starting currents.
  • Brazed plate heat exchanger consists of stainless steel plates permanently brazed with pure copper filter (for small models) .
  • High efficiency direct expansion (DX) shell and tube type coolers with inner grooved tubes to optimize the cooler’s efficiency (for large models).
  • Coolers are tested and stamped for refrigerant side design pressure of 1,000 kPa (145 Psi) and for a maximum water side working pressure of 1,500 kPa (220 Psi).
  • Liquid, discharge and suction pipes are all hard copper pipes. They are formed using automated CNC pipe bending machines in order to minimize pipe-brazed joints which in turn increases system reliability.
  • Epoxy paint for all exposed copper piping system of the refrigeration circuit.
  • Components of each refrigeration circuit include liquid line solenoid valve, liquid line shut off valve, high safety pressure switch and disposable core type filter.
  • Unit is fully charged unit with R410a/R407c refrigerant.
  • Thermostatic expansion valve.
  • Free terminal for remote ON/OFF connection.
  • Free terminal for general alarm output.
  • Control voltage is 220-240V for all components.
  • Single point power connection for each electrical panel.
  • Starting contactors for compressors and condenser fan motors.
  • ON/OFF switch for each compressor.
  • Control circuit breaker for short circuit protection.
  • Short cycling protection for compressors (time delay).
  • Control transformer mounted & wired that shall supply all unit control voltage from main unit power supply to internal components such as (not limited to) solenoid valves, compressor motor protector, compressor crank case heater and microprocessor controller.
  • Microprocessor controller for full management of chiller operation and safety circuits.
  • Power supply monitor (phase failure relay) used to protect the power circuit against over or under voltage conditions and against phase loss or loss reversing conditions.
  • Nema 3X with IP54 minimum enclosure standard electrical panel. Two separate panels, one for power & the other for control.
  • Copper tubes copper fins coil.
  • Coil corrosion protection including polyurethane pre-coating (for aluminum fins) and polyurethane post-coating (for aluminum & copper fins).
  • Sound reduction options including low rpm condenser fan and compressor jacket.
  • Electronic expansion valve.
  • Pressure gauges for monitoring of refrigeration discharge and suction pressure.
  • Water flow switch installed to prevent operation of unit without evaporator water flow.
  • Cooler cladding of aluminum, stainless steel or painted galvanized steel {made from gauge 22 [0.7 mm (0.03 inch)}.
  • Cooler can be insulated with closed cell foam insulation of 25 mm (1 inch), 38 mm (1.5 inch) & 50 mm (2 inch) The insulation density is 48 kg/m3 (3 lb/ft3) with a K-factor of 0.035 W/(m.°K) [0.0203 BTUH/(ft.°F).
  • Main disconnect switch used to de-energize the power supply to the chiller during servicing or repairing works because of the door interlock with an external handle that is installed on the electric panel door.
  • Power factor correction used to improve the power factor level which improves system reliability, minimizes voltage drops and gives better power quality.
  • Earth leakage relay used in electrical installations with high earth impedance to prevent shock
  • Control transformer to supply power input to auxiliary components at 120 or 220 volts, such as (not limited to) bulk head light and GFI outlet.
  • Ampere-meter & volt-meter used to measure the power current & voltage consumption Ampere-meter is used for each phase.
  • 120 volt power supply connected through the transformer to provide a 120 volt single phase circuit that is used to operate the electric appliances at site such as laptops, tablets and cell phones.
  • Speed regulator for condenser fan motors used to permit the unit to operate in low ambient temperature.
  • Dual power connection, one power entry for compressors & the second for the rest of the unit.
  • External over load for each compressor.
  • External over load for each condenser fan motor.
  • Circuit breaker for each compressor.
  • Circuit breaker for each condenser fan motor.
  • Nema 4x electrical panels made from galvanized steel.
  • Nema 4x electrical panels made from stainless steel.
  • Cooler tape heater protection down to 0°C (32°F), -18°C (0°F) & -29°C (-20°F).